Environtech Lab

Water Testing

Soil Testing

Feel Fee To Call Us

Waste-Water-Testing

Discharge of Water Treatment Plant (WTP), Effluent Treatment Plant (ETP) and Sewerage Treatment Plant (STP) by their Standard parameters at inlet and outlet point to find out the effectiveness of the treatment system. Waste Water Testing is carried out as per our Rolex Cellini Date Replica scope of accreditation by NABL (NABL Certified Lab).

 

S.No.

Specific Tests Performed

Test Method/Standard Against Which Tests Are Performed

1

pH

IS:3025,(Part-11)2002/APHA 22ND Edition:2012

2

Total dissolved solids

IS:3025,(Part-15)2006/APHA 22ND Edition:2012

3

Total suspended solids

IS:3025,(Part-17)2002/APHA 22ND Edition:2012

4

Ammonical nitrogen as NH3

IS:3025,(Part-34)2003/APHA 22ND Edition:2012

5

Dissolved oxygen

IS:3025,(Part-38)2003/APHA 22ND Edition:2012

6

BOD

IS:3025,(Part-44):2003/APHA 22ND Edition:2012

7

COD Fake Rolex Submariner

IS:3025,(Part-58)2006/APHA 22ND Edition:2012

8

Oil & greases

IS:3025,(Part-39)2003/APHA 22ND Edition:2012

9

Total Kjeldahl Nitrogen as N

IS:3025,(Part-34)2003/APHA 22ND Edition:2012

 

Microbiological-Testing

ETL undertakes complete range of Microbiological Testing like Total plate IWC Big Pilot Replica count, bacterial Count, Coliform Count, E.coli, Yeast and Mould, Salmonella, Shigella, Fungal Count, Faecal Streptococci, Bacillus Hublot Techframe Replica anthraces, Clostridium Spp, Pseudomonas aeruginosa.

Water-Testing

To check the sustainability for domestic, irrigation, industrial and Replica Audemars Piguet construction purposes including natural mineral water and packaged drinking water for parameters meeting our scope of accreditation by NABL (NABL Certified Lab). For more about Water Testing call us - icon0172-4630081 

 
 

S.No.

Specific Tests Performed

Test Method/Standard Against Which Tests Are Performed

1

pH

IS:3025,(Part-11)2002/APHA 22ND Edition:2012

2

Total dissolved solids

IS:3025,(Part-16)2006 APHA 22ND Edition:2012

3

Turbidity

IS:3025,(Part-10)2006/APHA 22ND Edition:2012

4

Alkalinity

IS:3025,(Part-23)2003/APHA 22ND Edition:2012

5

Acidity

IS:3025,(Part-22)2003/APHA 22ND Edition:2012

6

Total Hardness as CaCO3

IS:3025,(Part-21)2002/APHA 22ND Edition:2012

7

Calcium

IS:3025,(Part-40)2003/APHA 22ND Edition:2012

8

Magnesium

IS:3025,(Part-46)2003/APHA 22ND Edition:2012

9

Chloride

IS:3025,(Part-32)2003/APHA 22ND Edition:2012

10

Sulphate

IS:3025,(Part-24)1992/APHA 22ND Edition:2012

11

Residual free chlorine

IS:3025,(Part-26)2003/APHA 22ND Edition:2012

12

Iron

IS:3025,(Part-53):2003/APHA 22ND Edition:2012

13

Color

IS:3025,(Part-4)2002/APHA 22ND Edition:2012

14

Fluoride

 IS:3025,(Part-60) : 2008/APHA 22ND Edition:2012

15

Nitrate

IS:3025,(Part-34)2003/APHA 22ND Edition:2012

16

Nitrite

IS:3025,(Part-34)2003/APHA 22ND Edition:2012

17

Sodium

IS:3025,(Part-45)2003/APHA 22ND Edition:2012

18

potassium

IS:3025,(Part-45)2003/APHA 22ND Edition:2012

19

Silica as SiO2

Is:3025,(part35):2003/APHA 22ND Edition:2012

20

Temperature

IS :3025 (Part-9)2003/APHA 22ND Edition:2012

21

Sulphide Omega Hour Vision Replica

IS :3025 (Part-29)1986,Reff-2003/APHA 22ND Edition:2012

Ambient-Air

ETL undertakes a range of Ambient Air monitoring the 8-24 hours Replica Audemars Piguet sampling at site for significant parameters as per specification and requirement to comply with National/International Standards and scope of accreditation by NABL (NABL Certified Lab).

 

S.No.

Specific tests performed

Test Method / Standard against which tests are performed

1

Suspended particulate matter(PM 2.5)

IS:5182(Pt -4) 1999 Reaffirmed :2005

/Gravimetric method CPCB Guidelines:2011

2

Respirable suspended particulate matter(PM 10)

IS:5182(Pt -23):2006

 

3

Sulphur dioxide

IS:5182(Pt-2):1999 reaffirmed 2001

4

Nitrogen Dioxide

IS:5182(Pt-6):2006 Audemars Piguet Royal Oak Replica

Soil-Testing

Environ Tech Lab also undertakes the Soil Profile study and its detailed (physical and chemical) testing for its chemical characteristics for agriculture use and groundwater pollution. Testing is carried out as per our scope of accreditation by NABL (NABL Certified Lab). For more about Soil Testing Call us -icon 0172-4630081

 

S.No.

Specific tests performed omega Speedmaster replica

Test Method / Standard against which tests are performed

1

Soil moisture content

USDA :1954-Reaffirmed2010, Page 107 / IS2720(P-2) Reaffirmed:2002

2

Bulk density

USDA :1954-Reaffirmed 2010, Page 121

3

Water soluble solids Rolex Sky-Dweller Replica

USDA :1954-Reaffirmed 2010, Page 38/ IS2720(P-21) Reaffirmed:2006

4

Water holding capacity

USDA:1954-Reaffirmed 2010,  Page 39

5

pH

IS:2720(Pt-26):2007

6

Conductivity

IS:14767:2000

7

organic matter

IS:2720(Pt-22):2001

8

Chloride

USDA:1954-Reaffirmed 2010,  Page 133

9

Cations Exchange Capacity

IS:2720(Pt-24):1976 reaffirmed :2005

10

Soluble SO4 (Total)

IS:2720(pt-27):1977  reaffirmed :2005

11

Available phosphorus/Total phosphorus omega Speedmaster replica

USDA:1954-Reaffirmed 2010,  Page 134& Method in Environmental Analysis Water, Soil and Air Edition 2000

12

Available Nitrogen and nitrogenous compounds

IS:14684:1999 Reaffirmed 2005& Method in Environmental Analysis Water, Soil and Air Edition  2000

13

Total  kjeldahl nitrogen

IS:14684:1999 Reaffirmed  2005& Method in Environmental Analysis Water, Soil and Air Edition  2000

14

Ca and Mg in soil saturation extract

USDA:1954-Reaffirmed 2010,  Page 94

Stack-Emission

Environ tech Lab undertakes a range of Stack Emission monitoring of 30 min sampling of moving gas stream in confined space such as duct, chimneys and Breitling Navitimer Replica flues for significant parameters as per specification and requirement to comply with National/International Standards as per scope of accreditation by NABL (NABL Certified Lab).

 

S.No.

Specific tests performed

Test Method / Standard against which tests are performed

1

Sulphur dioxide

IS:11255(Pt-2):1985    reaffirmed 2003

2

Oxides of nitrogen

IS:11255(Pt-7):2005   

3

Particulate matter TAG Heuer Link Replica

IS:11255(Pt -1):1985 reaffirmed 2003

Illumination-Monitoring

EnvironTechLab undertakes the IWC Portugieser Replica monitoring of Lux (Luminous Intensity) for various sites like office, Factory, Hotel, Store, Hospital, School Panerai Radiomir 1940 Replica etc.

Noise-Level

Environ Tech Lab undertakes a monitoring of Piaget Possession Replica various type of indoor and outdoor source of noise as per scope of accreditation by NABL (NABL Certified Lab). We provide Noise Testing, noise abatement and noise Chopard Classic Replica mitigation services.